İçeriğe geç
Endotoxin Filtration | ELITE — Erözgün Makina
All products

ELITE / ENDOTOXIN CONTROL

Against an unseen
risk.

Endotoxin filtration systems

Support water safety in haemodialysis and sterilisation units with a measurable barrier.

Explore the solution
FILTRATION SYSTEM03 / PROTECTION
Endotoxin filtration system
Advanced membrane technology. Continuous control.
PERFORMANCE TARGET
<0.005 EU/ml
BACTERIAL BARRIER
>%99,9999
MEMBRANE PORE SIZE
≤6000 Da
APPLICATION
01

Water that looks clean.
Not necessarily safe.

Endotoxins are microscopic contaminants that can pose serious health and process risks even when water appears chemically clean.

Keeping LAL values under control in haemodialysis units and sterilisation centres is a critical step for patient safety and validation processes.

Why are endotoxins critical?

Product water should be monitored regularly to reduce infection risk, verify treatment performance and establish a sustainable safety barrier.

A lasting solution
that starts with a call.

Applications can be integrated into existing systems or designed from scratch and managed as one process from site survey to commissioning.

  1. 01

    On-site technical survey

    Existing infrastructure, samples and operating conditions are assessed.

  2. 02

    Source identification

    The endotoxin source and risk points are analysed.

  3. 03

    Filtration design

    The appropriate membrane and integration method are determined.

  4. 04

    Validation and commissioning

    Results are measured through performance tests and documented.

Advanced membrane.
Stable performance.

Filtration performance is designed by assessing pore structure, bacterial barrier, regulatory compliance and flow rate together.

01

Ultra-fine pores

Modules with pore sizes up to 6,000 Daltons help retain endotoxin particles.

02

Maximum bacterial barrier

Long-lasting barrier performance is targeted with a capture rate above 99.9999%.

03

Pharmacopoeia compliance

Design aligned with European Pharmacopoeia LAL requirements and reportable validation.

04

High water flow

Permanent hydrophilic modification reduces flow loss and supports operational continuity.

<0.005EU/ml

Performance target for product water

The result is visible.
Safety is verified.

The process is monitored until product-water values stabilise within target limits. Public Health laboratory tests and performance verification records support a sustainable safety approach at your facility.

FiltrationSampleAnalysisReport

LET US PLAN FOR YOUR FACILITY TOGETHER

Your safety barrier
let us strengthen together.

Contact us
PHONE+90 312 504 64 60MOBILE+90 553 240 63 73
ADDRESSAhi Evran OSB, Dulkadiroğlu Sokak No:6
06935 Sincan / Ankara